STORAGE
SECTION 6
CMD-4081850 / 90-860094030 SEPTEMBER 2003 Page 133
24. Remove the seawater pump impeller for storage:
a. Remove the seawater pump cover mounting screws, and remove the cover and
gasket.
b. Ease the impeller off the pump shaft with two screwdrivers.
c. Reinstall the cover for storage.
NOTE: Pump shown removed for visual clarity only.
71366
a
b
c
d
e
Typical
a-Seawater Pump Housing
b-Cover Screws
c-Cover
d-Gasket
e-Impeller
IMPORTANT: It is recommended that others be informed to NOT operate the engine.
25. Place a CAUTION TAG at instrument panel and in engine compartment stating that the
seawater pump is out - Do NOT operate engine.
CAUTION
Sterndrive unit should be stored in full DOWN / IN position. Universal Joint bellows
may develop a set if unit is stored in raised position and may fail when unit is
returned to service.
26. Place sterndrive unit in the full DOWN / IN position.
0087
Battery
Follow the battery manufacturer’s instructions for storage.